Appliance guides

Air conditioner error codes and fault guides

Browse 194 published, evidence-gated Air conditioner guides. Each page states the supported model and region, official source, safe checks, and the point to stop.

194Published guides
1Current page
9Total pages
Verified catalog

Air conditioner fault guides

1–24 of 194

AEGHigh attention
Air conditionerL3

portable-air-conditioner airflow or system fault

L3 is identified by AEG support as portable-air-conditioner airflow or system fault. Follow the official, model-scoped checks and service boundary below.

AEGCheck soon
Air conditionerP1

portable-air-conditioner water-tank or drainage condition

P1 is identified by AEG support as portable-air-conditioner water-tank or drainage condition. Follow the official, model-scoped checks and service boundary below.

BekoUrgent
Air conditionerRun lamp ×1

an indoor-temperature-sensor fault

Run lamp ×1 is identified in Beko's official model-scoped manual as an indoor-temperature-sensor fault. Use only the checks and safety boundary below.

BekoUrgent
Air conditionerRun lamp ×2

an indoor-pipe-temperature-sensor fault

Run lamp ×2 is identified in Beko's official model-scoped manual as an indoor-pipe-temperature-sensor fault. Use only the checks and safety boundary below.

BekoUrgent
Air conditionerRun lamp ×5

outdoor-discharge-temperature protection, incorrect electrical connections, high current, or high pressure

Run lamp ×5 is identified in Beko's official model-scoped manual as outdoor-discharge-temperature protection, incorrect electrical connections, high current, or high pressure. Use only the checks and safety boundary below.

DaikinUrgent
Air conditionerA1

indoor printed-circuit-board defect

A1 is listed in Daikin's official, model-scoped air-conditioner fault table as indoor printed-circuit-board defect.

DaikinUrgent
Air conditionerA5

high-pressure control or freeze-up protector operation

A5 is listed in Daikin's official, model-scoped air-conditioner fault table as high-pressure control or freeze-up protector operation.

DaikinUrgent
Air conditionerA6

indoor fan-motor fault

A6 is listed in Daikin's official, model-scoped air-conditioner fault table as indoor fan-motor fault.

DaikinHigh attention
Air conditionerC4

heat-exchanger temperature sensor fault

C4 is listed in Daikin's official, model-scoped air-conditioner fault table as heat-exchanger temperature sensor fault.

DaikinHigh attention
Air conditionerC9

suction-air temperature sensor fault

C9 is listed in Daikin's official, model-scoped air-conditioner fault table as suction-air temperature sensor fault.

DaikinUrgent
Air conditionerE1

outdoor circuit-board fault

E1 is listed in Daikin's official, model-scoped air-conditioner fault table as outdoor circuit-board fault.

DaikinUrgent
Air conditionerE5

compressor overload protector operation

E5 is listed in Daikin's official, model-scoped air-conditioner fault table as compressor overload protector operation.

DaikinUrgent
Air conditionerE6

compressor start-up fault

E6 is listed in Daikin's official, model-scoped air-conditioner fault table as compressor start-up fault.

DaikinUrgent
Air conditionerE7

outdoor DC fan-motor fault

E7 is listed in Daikin's official, model-scoped air-conditioner fault table as outdoor DC fan-motor fault.

DaikinHigh attention
Air conditionerEA

cooling/heating switching error

EA is listed in Daikin's official, model-scoped air-conditioner fault table as cooling/heating switching error.

DaikinUrgent
Air conditionerF3

high discharge-pipe temperature control

F3 is listed in Daikin's official, model-scoped air-conditioner fault table as high discharge-pipe temperature control.

DaikinUrgent
Air conditionerF6

high-pressure control during cooling

F6 is listed in Daikin's official, model-scoped air-conditioner fault table as high-pressure control during cooling.

DaikinHigh attention
Air conditionerH0

outdoor sensor fault

H0 is listed in Daikin's official, model-scoped air-conditioner fault table as outdoor sensor fault.

DaikinUrgent
Air conditionerH6

operation halted by a compressor position-detection sensor fault

H6 is listed in Daikin's official, model-scoped air-conditioner fault table as operation halted by a compressor position-detection sensor fault.

DaikinUrgent
Air conditionerH8

DC current-sensor fault

H8 is listed in Daikin's official, model-scoped air-conditioner fault table as DC current-sensor fault.

DaikinHigh attention
Air conditionerH9

outdoor suction-air temperature sensor fault

H9 is listed in Daikin's official, model-scoped air-conditioner fault table as outdoor suction-air temperature sensor fault.

DaikinUrgent
Air conditionerJ3

discharge-pipe temperature sensor fault

J3 is listed in Daikin's official, model-scoped air-conditioner fault table as discharge-pipe temperature sensor fault.

DaikinHigh attention
Air conditionerJ6

outdoor heat-exchanger temperature sensor fault

J6 is listed in Daikin's official, model-scoped air-conditioner fault table as outdoor heat-exchanger temperature sensor fault.

DaikinUrgent
Air conditionerL3

electrical-parts heat fault

L3 is listed in Daikin's official, model-scoped air-conditioner fault table as electrical-parts heat fault.