49–72 of 194

HaierUrgent
Air conditionerF23

compressor U/V/W-phase overcurrent

F23 is identified by Haier support as compressor U/V/W-phase overcurrent. Follow the official, model-scoped checks and service boundary below.

HaierUrgent
Air conditionerF24

CT detection current abnormal protection

F24 is identified by Haier support as CT detection current abnormal protection. Follow the official, model-scoped checks and service boundary below.

HaierUrgent
Air conditionerF25

abnormal compressor discharge sensor

F25 is identified by Haier support as abnormal compressor discharge sensor. Follow the official, model-scoped checks and service boundary below.

HaierUrgent
Air conditionerF27

compressor current-sampling circuit fault

F27 is identified by Haier support as compressor current-sampling circuit fault. Follow the official, model-scoped checks and service boundary below.

HaierUrgent
Air conditionerF28

compressor position-detection circuit fault

F28 is identified by Haier support as compressor position-detection circuit fault. Follow the official, model-scoped checks and service boundary below.

HaierUrgent
Air conditionerF3

communication error between the power module and main PCB

F3 is identified by Haier support as communication error between the power module and main PCB. Follow the official, model-scoped checks and service boundary below.

HaierUrgent
Air conditionerF35

compressor driver-board failure

F35 is identified by Haier support as compressor driver-board failure. Follow the official, model-scoped checks and service boundary below.

HaierUrgent
Air conditionerF4

compressor discharge-temperature protection

F4 is identified by Haier support as compressor discharge-temperature protection. Follow the official, model-scoped checks and service boundary below.

HaierUrgent
Air conditionerF43

model-matching abnormality

F43 is identified by Haier support as model-matching abnormality. Follow the official, model-scoped checks and service boundary below.

HaierHigh attention
Air conditionerF6

outdoor ambient sensor failure

F6 is identified by Haier support as outdoor ambient sensor failure. Follow the official, model-scoped checks and service boundary below.

HaierHigh attention
Air conditionerF7

suction temperature sensor failure

F7 is identified by Haier support as suction temperature sensor failure. Follow the official, model-scoped checks and service boundary below.

HaierHigh attention
Air conditionerF8

DC fan motor malfunction

F8 is identified by Haier support as DC fan motor malfunction. Follow the official, model-scoped checks and service boundary below.

HaierUrgent
Air conditionerFE

fixed-frequency refrigerant-leak detection malfunction

FE is identified by Haier support as fixed-frequency refrigerant-leak detection malfunction. Follow the official, model-scoped checks and service boundary below.

MideaHigh attention
Air conditionerE0

EEPROM error

E0 is identified by Midea support as EEPROM error. Follow the official, model-scoped checks and service boundary below.

MideaHigh attention
Air conditionerE0

EEPROM error

E0 is identified by Midea support as EEPROM error. Follow the official, model-scoped checks and service boundary below.

MideaHigh attention
Air conditionerE0

EEPROM error

E0 is identified by Midea support as EEPROM error. Follow the official, model-scoped checks and service boundary below.

MideaHigh attention
Air conditionerE1

room-temperature sensor error

E1 is identified by Midea support as room-temperature sensor error. Follow the official, model-scoped checks and service boundary below.

MideaHigh attention
Air conditionerE1

room-temperature sensor error

E1 is identified by Midea support as room-temperature sensor error. Follow the official, model-scoped checks and service boundary below.

MideaHigh attention
Air conditionerE1

room-temperature sensor error

E1 is identified by Midea support as room-temperature sensor error. Follow the official, model-scoped checks and service boundary below.

MideaHigh attention
Air conditionerE2

evaporator-temperature sensor error

E2 is identified by Midea support as evaporator-temperature sensor error. Follow the official, model-scoped checks and service boundary below.

MideaHigh attention
Air conditionerE2

evaporator-temperature sensor error

E2 is identified by Midea support as evaporator-temperature sensor error. Follow the official, model-scoped checks and service boundary below.

MideaHigh attention
Air conditionerE2

evaporator-temperature sensor error

E2 is identified by Midea support as evaporator-temperature sensor error. Follow the official, model-scoped checks and service boundary below.

MideaHigh attention
Air conditionerE3

condenser-temperature sensor error on applicable models

E3 is identified by Midea support as condenser-temperature sensor error on applicable models. Follow the official, model-scoped checks and service boundary below.

MideaHigh attention
Air conditionerE3

condenser-temperature sensor error

E3 is identified by Midea support as condenser-temperature sensor error. Follow the official, model-scoped checks and service boundary below.