Vaillant Heat pump F.731 error
F.731 is identified by Vaillant support as refrigerant high-pressure switch open. Follow the official, model-scoped checks and service boundary below.
What F.731 means
Vaillant Heat pump F.731: refrigerant high-pressure switch open. This interpretation applies to Vaillant heat-pump models covered by the linked official UK heat-pump fault-code page in United Kingdom / English.
- Model scope
- Vaillant heat-pump models covered by the linked official UK heat-pump fault-code page
- Region
- United Kingdom / English
- Verified
refrigerant high-pressure switch open
Isolate the appliance when safe. Contact the heating installer or Vaillant engineer; do not reset repeatedly or open the refrigerant, pressure, or electrical system. Do not open fixed panels or test live circuits.
Typical symptoms
Fault area and what the code does not prove
Separate the manufacturer-defined condition from components that still need exact-model diagnosis.
Safe next steps
- 1Confirm the exact Vaillant Heat pump F.731 model and displayed code before taking action.
- 2Keep the appliance in a safe state and use only the external checks named in the official source.
- 3If the condition remains, stop and arrange qualified service; do not open panels or bypass a safety device.
Step-by-step diagnosis
- 1Photograph the complete F.731 display before changing controls or removing power
- 2Confirm that the full model number is covered by this scope: Vaillant heat-pump models covered by the linked official UK heat-pump fault-code page
- 3Confirm that the observed condition matches the published meaning: refrigerant high-pressure switch open
- 4Published check — Contact the heating installer or Vaillant engineer
- 5Published check — do not reset repeatedly or open the refrigerant, pressure, or electrical system
- 6Stop at the published service boundary after these actions
- 7do not add a restart or test cycle that Vaillant does not specify for F.731
- 8Published check — Give service the F.731 photo, full model and serial number, when it appeared, and the result of every published external check
- 9Stop at the published service boundary after these actions; do not add a restart or test cycle that Vaillant does not specify for F.731
Service-safe actions
- 1Contact the heating installer or Vaillant engineer
- 2do not reset repeatedly or open the refrigerant, pressure, or electrical system
- 3Give service the F.731 photo, full model and serial number, when it appeared, and the result of every published external check
Repair planning
F.731 cost planning: The source-listed safety check is usually €0. €140–€320 is a typical Europe planning range for diagnosis before parts; it is not Vaillant pricing. Ask for separate diagnosis, parts, labor, and call-out lines on the quote.
F.731 time plan: 5–10 minutes to document and isolate safely; 30–90 minutes is a typical diagnostic visit before any model-specific repair.
Phone camera for the complete F.731 display, Full model and serial number, Power or water isolation access as described by the official procedure
F.731 parts decision: No component should be ordered from F.731 alone. The documented fault area is “refrigerant high-pressure switch open”; the technician must identify the failed model-specific part and revision.
What not to do
- Do not open fixed panels, test live circuits, bypass protection, or keep operating the appliance after an urgent stop instruction
- Do not run an extra test cycle after the source tells you to stop or arrange service for F.731
Preventive maintenance
- 1Follow the exact Vaillant maintenance schedule for the heat pump and keep the model, serial number, and service history available
- 2If F.731 begins recurring despite the documented maintenance, stop repeating the same action and request exact-model diagnosis
Frequently asked questions
What exactly does F.731 identify?
Vaillant identifies it as refrigerant high-pressure switch open.
Which action is actually supported for F.731?
Contact the heating installer or Vaillant engineer; do not reset repeatedly or open the refrigerant, pressure, or electrical system; Give service the F.731 photo, full model and serial number, when it appeared, and the result of every published external check.
Can I run another test after F.731?
Not unless the official procedure above explicitly includes it. Complete the safe external actions, then keep the appliance stopped at the service boundary.
Does F.731 prove which part failed?
No. It identifies “refrigerant high-pressure switch open”; parts are selected only after the exact model and failed function are confirmed.
What information should accompany a service request?
The F.731 photo, full model and serial number, the operating stage when it appeared, and the result of each published check.